Forget? NEVER! 9-11-01
 
LODD STATS
 
Custom Search
 

 
 
More 5" Hose Failures!
Thursday, October 15, 2009 
-
We have had seven sections over the past few years separate at the coupling. Fortunately we did not have nay injuries. The coupling does not break but the hose slips out of the coupling. After extensive investigation and meeting with the manufacturer it was discovered that they are no longer using that style coupling in their manufacturing of LDH. The problem hose had a narrow collar around the hose with a black plastic insert from the coupling. They now only use an aluminum insert instead of the plastic. The older hose had a wider collar with a blue plastic ring that went between the outer metal collar and the hose. This set up had the black plastic insert but with the wider collar and with the extra blue plastic ring the gripping surface was greater and we have had no reported issues with that arrangement.

LESSONS LEARNED:

Always position yourself in a safe place if possible when testing or using 5" LDH. Inspect and investigate all hose failures for potential similarities and follow NFPA and manufacturer recommendations to the letter.



Notification

USE OF INFORMATION FROM FirefighterCloseCalls.com and The Secret List should be passed along to FIREFIGHTERS and those who support (or are supposed to support!) us! Credit shall be given to www.firefighterclosecalls.com and if you are truly committed to firefighter safety, that should be no problem. If you aren't, and you don't give us credit and try to prostitute this stuff as your own, we'll find you and expose you. We Promise. Odd's are... our mailing list is bigger than yours!